Description
- Type: Closed-return, atmospheric-type wind tunnel
- Refrigerated for all-year operation
Test Chamber Dimensions
- Height: 1.8 m (6 ft.)
- Width: 2.7 m (9 ft.)
- Length: 6.1 m (20 ft.)
Tunnel Accessibility
- Model delivery access door - (10.5 ft. w by 10.67 ft. high)
- Balance chamber access door - (9.08 ft. w by 8.25 ft. high)
- Diffuser access hatch - (8 ft. high by 10 ft. wide)
- Personnel access door - (4.5 ft. wide by 5.25 ft. high)
Performance and Capability
- Continuous air speeds from 50 to 350 knots
- Mach number variation ±0.005 Mach
- Year-round temperature as low as -25°F, controllable to +/-1°F
- Supercooled water droplets between 15 and 50 microns
- Water content controllable between 0.2 and 2.5 g/m3 can be produced to form an icing cloud 6 ft by 5 ft
- 8.67 ft. diameter turntable can be rotated ±20 degrees
General Support Service Systems
- Heated air
- 150-psig at flows up to 5-lb/sec to temps up to 500°F
- 125-psig at flows up to 0.1 lb/s to temps up to 700°F
- Steam service at 40-psig
- Service or shop air at 125-psig
- Altitude exhaust - 26-in Hg at flows calibrated from 0.1 to 85-lbm/sec
- Force balance system
- Facility data recording equipment
Instrumentation
- Facility instrumentation data are displayed on WDPF pages
- Temperature measurements - oven inputs can handle type K-, T-, J-, or E-,thermocouples
- Pressure measurements
- Facility - Escort D data systems
- Model - 186 channel ESP data system
Imaging Technology
- Video and still imaging cameras
- High-speed photography
- Digital cameras
- Standard flow visualization techniques
- Laser sheet flow visualization
- Infrared thermography system
Data Processing
- Real time acquisition supported with Escort D data system
- 192 channels available for real time displays
- Electronically scanned pressure (ESP) system
- Scan rate of 10,000 ports/sec
- Three point calibration every 15 minutes
- Single and multi-cyclic scanning from one Record button
- Standard (CRT) output and Nonstandard (custom data plots, calculations or specific data) outputs available
- Facility workstations include a Silicon Graphics Model 4D Indigo system running IRIX 5.2 System V
|
|
 |
|
|
|
 |
|